Case Studies

BAXI Power HT Heats Local Swimming Pool

July 19, 2017
0 Comment

BAXI Power HT boilers were recently installed at a Dandenong Aquatic Centre to provide heating requirements for the commercial pool complex. The condensing technology adapts well to the heating requirements of a commercial swimming pool, maximising efficiency with the water temperature running at a low temperature.

(more…) read more →

Early Learning Centre LST Radiator Install

May 9, 2017
0 Comment

A new Early Learning Centre for children in Melbourne’s outer north underwent an installation of low surface temperature radiators. The system is powered by a BAXI Duo-Tec MP60kW, installed externally and flued with a stainless steel flue.

(more…) read more →

Ormond College Melb Uni Power HT Install

March 8, 2017
0 Comment

Retrofit upgrade to Ormond College at Melbourne University. Components of the original heating system dated back the the 1950’s, with the existing single Natural Gas atmospheric 600kW boiler being replaced by 4 x 150kW BAXI Power HT condensing boilers in cascade.

(more…) read more →

Powder Coated Rad Installs

November 21, 2016
0 Comment

A selection of installs showing use of custom colour powder coated radiator finishes. All our radiators can be custom powder coated to suit your customers decor and interior taste, this is particularly suited to high end and architectural installations. As per the case studies shown the popular colour choice of black suits many tastes, however any colour from the Dulux colour selection of over 100 colours can be matched.

(more…) read more →

Clarendon College Duo-Tec MP Install

November 21, 2016
0 Comment

Clarendon College Ballarat retrofit upgrade to existing heating boiler installation. The new system consisting of two Duo-Tec MP 110kW boilers is a fully modulating cascade with an integrated seamless flue system penetrating through the roof. The boiler room is located indoors on the top level of the science wing building.

(more…) read more →

Aged Care Low Surface Temperature Radiators

October 10, 2016
0 Comment

HydroHeat recently supplied Low Surface Temperature (LST) radiators for an installation to an Aged Care facility in Clarinda Victoria. The facility was a large Aged Care Residence undertaking major refurbishment and new build including complete heating system upgrade. Over 120 Henrad Compact LST Panel rads were installed by contractors GMR Mechanical services. GMR specialise in the Aged Care and Retirement Living Sector and choose Hydronic Heating as the optimum solution to commission for Aged Care and retirement living projects.

(more…) read more →

BAXI… the Global Brand

June 22, 2016
0 Comment

BAXI is the true global brand. BAXI hydronic heating boilers are specified for leading projects all around the world. The Seattle Housing Authority installed a total of 256 BAXI Luna3 Combi boilers into a large public housing estate in West Seattle, yielding a dividend of 37% savings in fuel consumption. The Luna3 Combi boiler was chosen as an elegant all in one (heating and DHW) backpack sized boiler with tankless hot water capabilities, making it ideal for the project. The compact size allowed freeing up valuable living space and fitting a stackable washer and dryer in the same closet as the combination heating and hot water boilers. The housing Authority is obliged to fix any mechanical problem within 24 hrs, hence installing a reliable boiler with low maintenance requirements was vital. These are the same Luna3 boilers as sold from our Breaside warehouse.

read more →

Melbourne Treasury Buildings

August 12, 2013
0 Comment

Victorian government goes with BAXI! After the successful rollout of Baxi boilers into the Old Treasury Building, the remainder of Melbourne’s Treasury buildings are now heated by Baxi Power HT boilers. The changeover from the old system to the new Baxi system was performed by A.G. Coombs over the course of a weekend and was a great success for all involved.

Download Design Schematic:
System Design Schematic - 4 Power HT Cascade

read more →

Mort St Canberra Office Block Retrofit

October 2, 2012
0 Comment

Retrofit upgrade to a 45 year old building over 5,400m2. The existing electric heating system was removed and replaced with high efficiency BAXI gas fired boilers which played a key part in reducing the buildings carbon footprint and achieving the target NABERS 4.5 star rating. BAXI PowerHT condensing boilers were selected for their high efficiency, compact size and the modular arrangement which made tham easy to install under restricted space conditions. The boilers have been in operation for two heating seasons and the maintenance contractors have provided positive feedback regarding their reliability and operation. The plant room contains 3 x 100kW Baxi PowerHT boilers in cascade controlled by a RVA47 Sequence Controller.

(more…) read more →

University of Launceston

May 22, 2012
0 Comment

The University of Launceston is now heated by Baxi PowerHT boilers installed with a RVA47 Sequence Controller and run by the Building Management System. This system has been designed to operate at maximum efficiency with underfloor heating and oversized fan coils for air handling.

Download Design Schematic:
System Design Schematic - 4 Power HT Cascade

read more →